Hinweise:
a)
\Theta_S = 2000\,A \\ R_L = R_{L,1} + \frac{1}{2} = 53,0516 \, kAV^{-1}s^{-1} \\ R_S = 1,5915 \, kAV^{-1}s^{-1} \\ R_R = 0,5305 \, kAV^{-1}s^{-1} \\ \Phi = 36,2492 mVs |
Ersatzschaltbild
b)
c)
d)
e)
f)
1.)
a)
R_f = 4,4 \, \Omega \\ P_{fV,n} = 11\,kW |
b)
I_{A,n} = 140ß,0909\,A \\ R_A = 10,0728\, m\Omega \\ |
c)
M_n = 6366,1977\,Nm \\ n_0 = 15,5 \, s^{-1} = 930\,min^{-1} |
2.)
U_{f,2} = 132\, V \\ M_2 = 3819,64\, Nm |
3.)
U_{f,3} = 220\,V \\ U_{A,3} = 203,4\, V |
4.)
R_V = 0,1461\Omega |
1.)
I_{A,n} = 62,2934\, A \\ R_A = 0,6208 \,\Omega \\ k_1\Phi_n = 17,8368\,Vs |
2.)
I_{f,2} = 5\,A \\ U_{A,2} = 299,0941 \,V\\ |
3.)
k_1\Phi_3 = 9,6319\,Vs \\ I_{f,3} = 2,7\,A |
1.)
a) - e)
R_f = 100\,\Omega\\ M_n = 895,245\, Nm\\ I_{A,n} = 320\,A \\ U_{i,n} = 484\,V \\ k_1\Phi_n = 18,15\,Vs \\ \eta = 0,9231 |
2.)
n_0 = 27,5482 s^{-1} \\ n_{0,\frac{U}{2}} = 27,5482 s^{-1} |
3.)
M_{d,n} = 924,37\, Nm\\ n_3 = 24,0220 s^{-1} |
4.)
Plot folgt in Hü: Zwei lineare Funktionen, die die y-Achse bei schneiden und mit unterschiedlichen Steigungen fallen. Bei halber Versorgungsspannung fällt die Kurve um den Faktor 4 schneller ab.